Lambeth have sent another demand letter to leaseholders, this time regarding fire safety requirements for flat entrance doors.
_
UPDATE: Lambeth Homeowners Association has taken this up with the head of Housing Scrutiny Councillor Simon Cordon who has written to (Janet Sharpe the Housing Operations Director at Lambeth Council who signed the letter) to say that her letter is confusing and alarming etc and should be withdrawn and replaced by a letter giving proper information. LHA recommend that you don’t anything for now, unless you wish to add to the tsunami of emails to Lambeth to say that you are unable to reply without sufficient information to form a judgement. It would be kinder to them to resist that temptation Antony Wynn – LHA
_
The door replacement scheme relates to Lambeth’s ongoing, multi-million-pound fire safety programme driven by post-Grenfell legislation, specifically the Fire Safety Act 2021, the Fire Safety (England) Regulations 2022, and the updated government fire door guidance published in August 2025. The legal duties regarding flat entrance doors in buildings over 11 metres are split between fire safety enforcement and leasehold property law. Under these laws, landlords and councils must actively manage fire risks in multi-occupied residential buildings, ensuring flat entrance doors and communal doors can hold back fire and smoke for at least 30 minutes.
The Fire Safety Act 2021 clarified that flat entrance doors and communal doors in multi-occupied buildings fall under the Fire Safety Order. The Fire Safety (England) Regulations 2022 (in force from January 2023) introduced regular checks and fire door information duties for blocks over 11 metres. For residential buildings over 11 metres tall, Lambeth Council is legally required to check communal fire doors every three months and inspect flat entrance doors annually.
In August 2025, government guidance on the Fire Safety (England) Regulations 2022 clarified that existing flat entrance doors do not always need to meet modern new-build standards if they are undamaged, fit their frame properly, and self-close and latch reliably. Replacement is typically needed when doors are non-compliant, damaged, altered, or a type identified as failing. Find out more here.
For existing buildings, doors must be repaired or replaced if a Fire Risk Assessment (FRA) or inspection shows they need to be replaced. The FRA was not included in the letter from Lambeth, and no prior communications were received that a inspection was being undertaken. No clarity has been given on why this letter has been sent now almost 4 years after the The Fire Safety (England) Regulations 2022 (in force from January 2023). No clarity has been given if/when inspections have been scheduled since January 2023.
PRERA understand this to be a blanket email/letter sent to all Leaseholders across Lambeth, not just on PRE. The Lambeth Housing Team were apparently not aware that the email, letter, or website notice was to go out before it was sent. They confirmed it’s not been issued as S20. Particularly unfairly the letter/email asks leaseholders to say whether or not we will use their scheme without any indication of costs or timelines. The letter/email also doesn’t define what their “reasonable timeframe” is after which we’ll be in breach of our lease is.
One residents who called Lambeth was provided with the following information: If you opt for the council scheme they do the work. If you go with the council scheme between now and March of next year the work is done in September of next year and you get a separate bill. If you sign up after March then the work is done in 2028. While the final cost will vary depending on the property and survey outcome, the Council intends to offer a range of payment options to assist leaseholders, including, payment in full with a 5% prompt payment discount, interest-free instalments over two years; or longer-term loan arrangements, subject to eligibility. The ballpark average price can range from £1500 to £4000 as rough estimate. If you wish to explore participation the Council’s appointed contractor to arrange a survey of your property. Following the survey, you will receive details of the proposed door specification, the cost of the works, available payment options and the anticipated installation timescale. You will then be able to decide whether you wish to proceed. There is no obligation to commit to the replacement works until you have received and reviewed this information.
Important information
- Older Doors Are Not Automatically Illegal. Under updated government fire door guidance (revised in August 2025), existing “notional” fire doors do not need to meet modern new-build certification standards just because they lack a modern test label or intumescent strips.
- When Replacement Is Actually Required. A door generally only needs replacing if it is a non-fire-rated door (like standard uPVC), has a damaged leaf or frame, cannot reliably self-close and latch, has excessive gaps, or is a specific model flagged by government testing as defective.
- Right to Challenge. If you believe your door is sound, the Leasehold Advisory Service provides template letters allowing you to request the specific Fire Risk Assessment (FRA) report that triggered the replacement demand.
Does the freeholder have to provide the Fire Risk Assessment (FRA) to leaseholders?
Not the full document automatically, but they are legally required to provide the relevant findings and fire safety information.
- Legal duty to share information: Under Article 21A of the Regulatory Reform (Fire Safety) Order 2005 (introduced by the Building Safety Act 2022), the “Responsible Person” (usually the freeholder or managing agent) must give residents clear, relevant information about:
- The risks to residents identified by the Fire Risk Assessment.
- The preventive and protective measures in place (including what is required for fire doors).
- The identity and contact details of the Responsible Person and the person who carried out the assessment.
- Requesting the full report: While there is no automatic statutory right to demand a copy of the complete FRA document, many freeholders provide it upon request. If they refuse to share the full report, they must still give you the specific written findings explaining why your door was flagged. If they fail to provide this information, your local Fire and Rescue Authority has the legal power to enforce Article 21A and compel them to comply. (Note: If your building is over 18 metres / 7 storeys, the Building Safety Act gives residents additional statutory rights to request prescribed fire safety documents directly from the Principal Accountable Person.)
Who has the onus to prove a door needs (or doesn’t need) replacing?
The onus is on the freeholder (Responsible Person) to demonstrate that an existing door is inadequate, not on the leaseholder to prove an older door meets modern certification standards.
In August 2025, the Ministry of Housing, Communities and Local Government (MHCLG) updated its official Fire Safety (England) Regulations 2022: fire door guidance specifically because freeholders and inspectors were wrongly forcing leaseholders to replace sound doors simply because they lacked modern test certificates.
- What the law actually requires: In buildings over 11 metres, the freeholder must use “best endeavours” to carry out annual visual checks of flat entrance doors. These checks are to verify that the door is undamaged, has no excessive gaps (generally no more than 4mm around the sides/top), and closes and latches fully on its own.
- Older (“notional” or “nominal”) doors: The August 2025 guidance explicitly states that existing doors do not need to meet modern new-build standards (FD30S). The absence of a modern certification label, intumescent strips, or smoke seals does not automatically make an older door unfit for purpose.
- How replacement is justified: If a freeholder demands that you replace a door, they must base that decision on an actual defect identified in a competent Fire Risk Assessment (e.g., physical damage, warping, a non-fire-rated replacement door, or excessive gaps that cannot be repaired) not merely a lack of paperwork. Even where issues exist, government guidance directs freeholders to prioritise repair (adjusting hinges, fitting a self-closer) over full replacement wherever possible.
Next Steps
Leaseholders would like to see Lambeth’s Fire Risk Assessment and understand the details of the FRA to confirm what has been looked at and when before making any decisions. A freedom of information request for the assessment related to 27-38 Bushell Close has been issued by a resident in that block. There is an online platform called ‘What do they know?’ which facilitates FOIs. Here is the link in case anyone wants to replicate:
https://www.whatdotheyknow.com/request/fire_risk_assessment_for_27_38_b
You can also:
- Check your lease: Confirm whether the flat entrance door is “demised” to you (making you responsible for its maintenance/ replacement) or retained by the freeholder* (*the freeholder can still pass the cost onto the leaseholder through service charge).
- Demand written reasons under Article 21A: Write to the freeholder or managing agent requesting the relevant section of the Fire Risk Assessment and the specific physical defects found on your door, citing the August 2025 MHCLG Fire Door Guidance.
- Challenge unreasonable demands: If the door is demised to you and the freeholder insists on a replacement without evidence of a physical defect, they cannot force you to pay unless they prove a breach of your lease covenant in the First-tier Tribunal (Property Chamber). (Note: If the door is deemed a “historical safety defect” dating back to the building’s construction or refurbishment, leaseholder protections under the Building Safety Act 2022 may also cap or eliminate your liability to pay.)
The email from Lambeth in full:
Dear leaseholder,
A recent fire risk assessment of your building identified some fire safety issues that require attention. We need your cooperation to help keep all residents safe.
Flat entrance doors
Some flat entrance doors require further assessment and may not meet current fire safety standards. Under the terms of your lease, you are responsible for ensuring your door complies.
Door Replacement Programme
To assist leaseholders, the council is offering a replacement programme through an approved contractor, ensuring doors meet the required standards and are properly certified. The full cost will be recharged to you. Payment options include payment in full, with a 5% prompt payment discount Interest-free instalments over two years and longer-term loans, subject to eligibility.
If you choose not to join the programme, you must arrange your own assessment and any necessary replacement. You will need the council’s written consent before starting work and must provide details of the door, installer and relevant compliance certification. The council may refuse consent where the proposed arrangements do not meet the required standards. Failure to address a non-compliant door within a reasonable period may constitute a breach of your lease and could result in enforcement action.
Keeping communal areas clear
Hallways, corridors, stairwells, landings and entrance lobbies are shared escape routes and must be kept clear at all times. Personal belongings, furniture, bicycles, mobility equipment and rubbish must not be stored in these areas unless expressly authorised by the council.Unauthorised items may be removed and disposed of, and associated costs may be recovered.
Next Steps
Please contact us within 14 days of receiving this email to:Confirm whether you wish to join the council’s door replacement programme; orExplain how you intend to demonstrate compliance through your own arrangements.If we do not hear from you, or satisfactory arrangements are not put in place, the council may take such action as it considers necessary to address the identified fire safety risks and secure compliance with the terms of the lease.If you have any questions, contact the Homeowner Advisor Team on 020 7926 1116 or email hmhomeownership@lambeth.gov.uk
We have also sent you a letter.
Thank you for your cooperation in helping us keep your building and neighbours safe.
Yours faithfully,
Janet Sharpe
Housing Operations Director
Lambeth Council